Powersolve PQP100 Series Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Fournisseurs d'énergie Powersolve PQP100 Series. Powersolve PQP100 Series User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 4
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England
Tel: 01635 521858 Fax: 01635 523771 Email: sales@powersolve.co.uk
AC-DC Battery Backed Power Supply
Input Voltage 90-264VAC, 47-63Hz / 127-373VDC (withstand 300VAC surge for 5 sec. without damage)
AC Input Current (typ.) PQP75: 1.5A at 115VAC / 1.0A at 230VAC
PQP100: 2A at 115VAC / 1.2A at 230VAC
Inrush Current 35A at 115VAC / 70A at 230VAC
Leakage Current <1mA at 264VAC
Output Voltage See Table
Output Current See Table
Voltage Adjust Range ±10% typical adjustment by potentiometer (CH1 only)
Voltage Tolerance CH1: ±2%, CH3: ±3%
Set Up, Rise Time PQP75: 800ms, 30ms at full load
PQP100: 800ms, 50ms at full load
Hold Up Time (typ.) 50ms at 230VAC / 8ms at 115VAC, full load
Overload Protection >110% of rated output power CH1/CH3 (GB/LB only) / >100% of rated output power for CH2
Protection type: Hiccup mode, recovers automatically
Overvoltage Protection 115-140% of rated output voltage for CH1
Protection type: latch off mode
Low Battery Cut Off 10V ±5% for 13.8V version / 20V ±5% for 27.6V version
Low Battery Signal <12V ±3% for 13.8V versions / <22V ±3% for 27.6V version
AC OK Signal TTL open collector output for G & L versions / Relay contact output for GB & LB versions
Operating Temp. Range -20°C to +70°C (with derating. see derating curves)
Operating Humidity 20-90% RH non-condensing
Storage Temp. Range -40°C to +85°C
Storage Humidity 10-90% RH non-condensing
Temperature Coefficient ±0.03%/°C (0-50°C) on CH1
Vibration 10-500Hz, 2G 10min./1 cycle, period for 60 min, each along X, Y & Z axis
Safety Standards meet UL60950-1, TUV EN60950-1 approved
Withstand Voltage I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC
Isolation Resistance I/P-O/P: 100MΩ / 500VDC
EMI Conduction & Radiation EN55022: 2006+A1 : 2007 Class B
Harmonic Current EN61000-3-2: 2006 Class A, EN61000-3-3 : 2008
EMS Immunity EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024
Cooling Free Air Convection
Dimensions 123(L) x 95(W) x 31(H) mm
Electrical Specification
Notes:
1. All parameters NOT specifically mentioned are measured at 230VAC input, rated load and 25°C ambient temperature
2. Ripple and noise are measured at 20MHz bandwidth by using a 12” twisted pair wire terminated with a 0.1µF ceramic & 47µF electrolytic capacitors across the output
3. Tolerance: includes set up tolerance, line regulation and load regulation
4. Line regulation is measured from low line to high line at rated load
5. Load regulation is measured from 10% to 100% rated load
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC Directives
7. Length of set up time is measured at cold start. Turning the power supply ON/OFF very quickly may lead to increased set up time
8. The total power output can not exceed the rated power, max. output current is per channel
9. CH2: Battery discharge current can not exceed 50% or the rated power
10. Do not connect the DC Output GND port to the Battery -ve port to prevent damage to the power supply
PQP75-100 Series
75-100W
1-3 Outputs with Battery Charger
Features
Universal AC Input
Auto Switch when Power Off (UPS Function)
Built-in Constant Current Limiting Circuit
Alarm Signals for AC OK & Battery Low
Short Circuit, Overload, Over Voltage Protections
Brown Out (AC Input Voltage Low) Protection
Battery Low Protection
Battery Polarity (by resettable fuses) Protection
Cooling by Free Air Convection
www.powersolve.co.uk
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - 75-100W

Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. EnglandTel: 01635 521858 Fax: 01635 523771 Email: [email protected] Batt

Page 2

Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. EnglandTel: 01635 521858 Fax: 01635 523771 Email: [email protected]

Page 3 - Derating Curves

Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. EnglandTel: 01635 521858 Fax: 01635 523771 Email: [email protected]

Page 4

Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. EnglandTel: 01635 521858 Fax: 01635 523771 Email: [email protected]

Commentaires sur ces manuels